What should incoming inspection establish?
Incoming inspection asks whether the delivered material matches the order and can be released under the agreed quality plan. It is different from qualifying a new material for a new application, and different again from diagnosing a failure after printing or dispensing.
Keep the questions separate. Receipt checks can find a wrong roll identity, damaged packaging or an incorrect width. Laboratory checks can assess selected properties under defined conditions. A converting or application trial evaluates behavior in the intended process. None of these steps automatically substitutes for the others.
An external defect also needs context. A damaged wrapper does not establish that the entire roll is unusable, while an intact wrapper does not confirm the material inside. Record observations and follow the agreed escalation process rather than deciding from appearance alone.
Establish the construction and acceptance basis first
Before comparing measurements, identify the ordered facestock and surface treatment, adhesive, liner and relevant construction revision. Include roll format and any agreed winding, splice, packing or documentation requirements. For linerless stock, use the applicable structure and process requirements rather than adding a liner field that does not exist.
Distinguish the documents:
- TDS: technical information for a grade or construction. Values may be typical rather than contractual acceptance limits; read the document’s wording and conditions.
- COA: a certificate of analysis may report results for an identified batch or lot. Check the actual fields, method references and relationship to the delivered rolls instead of assuming every listed property was tested on every roll.
- COC or conformity declaration: a statement of conformity whose scope depends on its wording. It is not automatically a substitute for numerical test results.
Document availability and content must be agreed with the supplier. This guide does not establish an AllinLabel COA service or a requirement for a COA with every order. If a required document is missing, follow the agreed hold-and-review process; a document not required by the purchase agreement is not automatically a rejection reason.
For interpretation of published material values, use how to read a label material datasheet. Keep this inspection record linked to the approved specification revision, not just a generic product name.
- 01
Identify delivery
- 02
Inspect receipt condition
- 03
Perform agreed checks
- 04
Review records
Unresolved information → Hold for review
- 05
Authorize disposition
Receiving checklist: identify the delivery before testing
Record the condition at receipt before changing packaging or unwinding material. Handle rolls using the approved site procedure. Where the supplier’s storage instructions or the test method require acclimatization or conditioning, follow those instructions and record what was done. Do not choose a universal waiting period for all papers, films and constructions.
| Check | Record or compare | If something differs |
|---|---|---|
| Order and shipment | Purchase reference, delivery reference, construction ID and revision | Identify which ordered line the material belongs to before release |
| Batch and roll identity | Supplier lot or batch, individual roll ID and any internal receipt ID | Keep mixed batches identifiable; do not merge them into one undocumented result |
| Quantity and units | Roll count and declared length, area or weight, as applicable | Reconcile like units; do not infer usable length from roll count alone |
| Packaging and transport condition | Wet, crushed, punctured or missing protection; time-stamped photographs | Preserve the evidence and identify the affected rolls for review |
| Roll and core condition | Visible edge damage, telescoping, core deformation or contamination | Record the location and extent without assuming the cause |
| Format and winding | Required width, core ID, roll diameter or weight limits and winding | Compare with the approved order and machine requirements, not a catalogue default |
| Accessible material surface | Visible marks, wrinkles, coating irregularities or adhesive at roll edges | Record the observation, roll location and sample identity; appearance alone may not identify the mechanism |
| Splices and identification | Splice marking, declared locations and restrictions where specified | Check the agreed requirements and preserve traceability during any trial |
| Documents and storage history | Required documents, material dates, stated storage or use-by conditions and known deviations | Separate missing information from a confirmed nonconformity and seek an authorized decision |
A check of the accessible surface does not inspect the full length of the roll. Do not describe it as a complete internal-defect check. Mark what was examined and what remains outside the inspection scope.
Choose laboratory checks for the actual risk
Do not run every test simply because it appears on a checklist. Select checks from the approved inspection plan, material history and intended use. Keep sampling separate from test selection: a measurement on one specimen does not establish the condition of an entire shipment.
The plan should define how lots, rolls and sample positions are selected, the required replicates and how results affect disposition. Record the plan reference. This guide does not prescribe an AQL, a fixed number of rolls or an acceptance threshold.
Where a standardized method is required, use the applicable full method and agreed revision. The FINAT reference below identifies method families; it is not a complete laboratory procedure or a statement that these methods are mandatory for every receipt.
| Property or question | Method family to discuss | Conditions to preserve in the record |
|---|---|---|
| Adhesion to a defined panel | Peel methods, such as FINAT FTM 1 or FTM 2 | Panel, preparation, peel geometry, dwell, speed, specimen width, environment and units |
| Separation from the release liner | Release methods, such as FINAT FTM 3 or FTM 4 | Construction, separation geometry, speed and specimen dimensions |
| Initial tack | A loop-tack method, such as FINAT FTM 9 | Contact surface, specimen preparation, settings and units |
| Resistance to sustained loading | A shear method, such as FINAT FTM 8 | Loading arrangement, bonded area, preparation, dwell, temperature and result definition |
| Dimensions or physical properties | The applicable agreed dimensional or material method | Component being measured, sample position, instrument, settings and units |
Peeling a label from its release liner is not the same test as peeling it from a panel. A hand-peel observation is useful to document, but should not be reported as a standardized numerical peel result.
Keep facestock caliper, liner caliper and total laminate thickness distinct. For any instrument result, record the equipment identity and relevant calibration status. Do not convert a typical TDS value into a pass/fail limit without an agreed specification.
Connect each result to a batch, roll and specimen
Keep the receiving record and laboratory record connected. A useful result can be traced back to the delivered roll, sample position and method conditions, with the original observations still available.
The blank records below are planning templates. They contain no measured results and are not a COA, certification or evidence that AllinLabel has inspected a shipment.
Receiving record fields
Receipt reference; receipt date; supplier; purchase reference; construction and specification revision; batch or lot; roll ID; quantities and units; inspection scope; packaging and roll observations; photograph references; required documents and status; storage or conditioning record; inspection-plan reference; inspector; disposition; authorized decision-maker; decision date; follow-up reference.
Test record fields
Receipt reference; batch or lot; roll ID; specimen ID and sample position; construction revision; property; method and revision; laboratory or operator; test date; instrument and calibration reference; specimen dimensions and direction; panel and preparation; application procedure; conditioning; dwell; temperature and humidity; test settings including speed, angle or load where applicable; measured value; unit; raw-data reference; failure mode; acceptance criterion and source; result assessment; deviations; review reference.
Record individual results before summarizing. If averages are used, retain the individual values, the number and identity of specimens, and the calculation basis. Distinguish repeated measurements of one specimen from independently selected specimens. An empty result is not zero, and “not tested” is not a pass.
Do not add a pass-rate chart to a blank template. If actual data is later published, include its source, construction, sample definition, conditions and acceptance basis before drawing conclusions.
Blank planning templates — not completed inspection records or a COA.
Decide release, hold or further review
Use the converter’s authorized quality process. The following are decision directions, not automatic release rules.
| Situation | Direction to consider | Preserve in the record |
|---|---|---|
| Required checks meet the agreed requirements | Release within the approved scope | Specification revision, results and release authority |
| Identity, required documents or results are unresolved | Hold the affected material pending review | Roll identities, missing information and follow-up owner |
| A confirmed result falls outside an agreed requirement | Open a nonconformance review and follow the agreed disposition process | Method conditions, raw results, affected scope and supplier communication |
| An alternative use or concession is proposed | Obtain explicit authorization before use | Approved restriction, affected quantity and decision reference |
Preserve packaging, retained samples and original records where required by the agreed procedure. Do not mix affected stock with released stock or change its identification while the issue is unresolved. A concession should not silently change the specification for future deliveries.
If a later print, die-cutting or application trial fails, compare the construction and process conditions before assigning a cause. Edge ooze, matrix breaks and print-adhesion problems can involve more than one variable. The receiving record provides a starting point for investigation, not proof that a particular party caused the failure.
Related diagnostics: edge ooze, matrix breaks and ink adhesion.
What this checklist does not prove
An incoming check does not establish every end-use property, future batch consistency, shelf life, regulatory compliance or production-line performance. A laboratory result on a standard panel does not qualify a different container or surface finish by itself.
Keep receipt inspection, new-material qualification and later failure analysis distinct. For critical applications, define the additional validation and approval requirements with the responsible quality and engineering teams. No universal tolerance, peel minimum, sample size or conditioning period is set by this guide.
Buyer FAQs
Does a COA replace incoming inspection?
Not automatically. Review what the document covers, how it relates to the delivery and what the purchase agreement requires. A COA can support the record; it does not by itself show the condition of each delivered roll or performance on the converter’s line.
Should every roll receive every laboratory test?
Use the agreed sampling and inspection plan. The scope depends on the material, risk and purchasing requirements. Neither testing one roll nor testing every accessible surface establishes all properties of a shipment.
Can typical TDS values be used as rejection limits?
Not without an agreed acceptance basis. Confirm whether the document states typical information, a guaranteed property or a contractual limit, and compare results obtained under the specified conditions.
How long should labelstock be conditioned before testing?
Follow the applicable method and material instructions. Record the actual conditions and duration. Do not apply one waiting period to every construction or confuse storage acclimatization with a test method’s conditioning requirements.
What should I send when reporting a suspected material problem?
Provide the order reference, construction, batch and roll identities, observed location, photographs, relevant raw measurements and test conditions. State the affected quantity and whether the issue was present at receipt or appeared during converting. Avoid sending customer-confidential artwork or records without permission.
Prepare a focused material enquiry
If a requirement is not yet defined, ask about the proposed construction and documentation before ordering. For a trial request, describe the application, substrate, printing and converting process, roll format and the checks you intend to perform. Sample arrangements and any supporting documents need confirmation for the specific enquiry.
Use the material catalogue to identify a family, the datasheet directory to locate published information, and the jumbo roll guide for roll-format questions.
Sources and method limits
- FINAT Technical Handbook public reference: identifies labelstock test-method families. This public brochure is not the full test procedure. Confirm the applicable full method and revision with the responsible laboratory.
- HERMA storage and climate guidance: illustrates the need to consider storage conditions and acclimatization. Its product guidance is not a universal AllinLabel storage specification.
- Avery Dennison supplier statement: a published example of traceability, identification and quality records in a supplier system. It does not describe AllinLabel’s procedures or establish requirements for every converter.
No AllinLabel incoming-inspection results or batch COAs are presented in this guide.